Click on [Clear] button to remove all marked signals.
Click on [Invert] button to change markings to contrary.

7.12.3. Skip initial state

This option allow for locking of sending of information on status of active inputs at
power connection. Information on inputs will be sent to server after the first change
from inactive to active status.
For the events "Power" and "Battery" no selection "Skip initial state" will cause
sending information about the power supply / battery on boot device regardless of
the power supply / battery state.

7.12.4. Power loss

One of device additional options is monitoring of power supply voltage. As short
voltage drop may follows at some facilities, it is possible to avoid reporting by
entering time after which information will be sent.
Value of this parameter means that voltage drop shall follow within this determined
time so that device recognizes it as real voltage drop and that information might be
sent.

7.12.5. Event: Input 3 (RC) and Input 4 (RC)

Virtual RC input (only for LX2N-4R), which allow you to send a report on status of
active inputs.

7.13. RESTRICTIONS

7.13.1. SMS Authorized phones

User may restrict remote access to the device (via SMS) for determined phone
numbers. A list of numbers (up to 5 numbers) determines which numbers are
allowed to connect with transmitter.
Available options:
 Deny all: means no available telephone communication.
 Allow all: means that telephone communication is possible from any phone.
 Allow chosen: means that telephone communication is possible only from these
numbers that are on the list. It is possible to list up to 5 phone numbers.
Select "Allow chosen" to get access to edition window. Enter another numbers and
click on [Add] button to send them to the below table. Position cursor on line with
number and click on "Remove" to remove number from table.
Click on "Remove all" to remove all numbers from table.
Note:
a) authorizing of coming SMS comes through comparing number of oncoming SMS
with numbers from table. It is allowable to enter only a part of number e.g. 1234.
As a result all numbers with this sequence will be authorized e.g.600123456 or
601234567.