Remote Connection - EBS LX2N Installation And Programming Manual

Table of Contents

Advertisement

6.3.5.2.

Remote connection

As provided above the device and software makes for complete configuration with
GPRS link or CSD channel. This programming mode requires definition of linking
parameters.
GPRS link
Activate file in Main menu and select Connection function (or after clicking on
icon on fast access bar) and click on GPRS tab to carry out configuration of this
mode.
On screen the following window shall appear:
Define:
 Name of connection e.g.: Remote
 Select name of analyzer e.g.: Primary
 Enter analyzer address e.g.: 87.128.125.8
 Enter port on which analyzer operates e.g. 7000
Click on [Add] button to confirm settings. Connections shall be saved (and inserted
in table). From this time on program shall enable remote connection to device and
reading and saving of parameters in LX memory shall be possible.
Notice: The following parameters: analyzer name, analyze address, port
relate to settings of
OSM.2007 receiver of monitoring system. Remote
programming is available only if above mentioned device (or software) is
used.
CSD link
Activate file in Main Menu and select Connection function (or after clicking on
icon on fast access bar) and click on GSM Modem tab to carry out configuration of
this mode.
On screen the window shall appear where it is possible to define:
 Name of connection e.g. Remote CSD
 Serial port where GSM modem is connected (e.g. Wavecom Fastrack)
 PIN code of SIM card installed in GSM modem e.g. 1111
 Serial port parameters: amount of bytes/sec. (e.g. 115200), data bytes (8),
parity (none), stop bytes (1)
LX2N_Manual_en-1.11i66
Page 18 / 56