3.3.
REMOTE
VERSION)
The device in version LX2N-4R provides 2 additional virtual inputs that can be
triggered by radio transmitters. The way of functioning should be configured by
GPRS configurator software.
Remote control programming procedure
Press PROG (B) and hold. After a moment, the red LED STATUS flash. If the button
is held longer, the red LED STATUS will flash second time and a third and then stop
blinking which would mean the exit from the programming process.
If the button will be released:
After the first STATUS LED flash, the transmitter will enter the programming
mode the channel is responsible for virtual input # 3. Status LED on. Pressing the
remote control button program in the transmitter memory. LED turns off to exit the
programming mode.
After the second STATUS LED flash, the transmitter will enter the
programming mode the channel is responsible for virtual input # 4. Status LED on.
Pressing the remote control button program in the transmitter memory. LED turns
off to exit the programming mode.
After the third STATUS LED flash, the transmitter will enter the erasing mode.
Press the PROG button again and wait to LED STATUS off. Release the button.
Erasing of pre-programmed remotes will be confirmed by lighting up STATUS LED
and OK.
3.4.

LX-ZAS POWER SUPPLY

The dedicated power supply LX-ZAS (product of EBS) possesses the following
parameters:
Parameter
Served batteries
Maximum voltage of charging battery
Charging current
Voltage of signaling of low level
Voltage of switch-off battery
as well as it characterizes with following proprieties:
 protection against opposite connecting battery.
 protection against excessive unloading battery:
The battery protects before damage in case of long-lasting fading the AC. In
case of lack the AC and unloading below voltage 9.5 V the battery becomes
separated from device automatically.
quick charging of the battery:
LX2N_Manual_en-1.11i66
CONTROL
CONFIGURATION
(ONLY
Value
Acid-leaded 12V
0.2A lub 1A (switched by jumper)
LX2N-4R
13.8V
11 V
9.5V
Page 10 / 56