Direct Access To Programming Mode With The "Dap" Code - 2 8 2 8 - AEI DK-2890 User Manual

Back-lit weatherproof rfid access control keypad
Table of Contents

Advertisement

DIRECT ACCESS TO PROGRAMMING MODE WITH "DAP" CODE -- 2 8 2 8
In case the Master Code is forgotten, apply the following procedures precisely to set keypad
into programming mode with DAP code:
1)
Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged.
2)
Switch ON power again. The keypad is in Power-up Mode for 1 minute. The buzzer gives
continuous beeps and the Status LED is flashing. This is the only time frame to accept the DAP
code.
3)
Press the Egress Button (the button connecting accross EG IN, (Terminal 7) and (-)GND,
(Terminal 8) once to enable the keypad for accepting DAP code. The power-up beep stops after
the Egress Button is pressed.
4)
Key in the DAP code
keypad is in programming mode like using Master Code. It is ready to accept new programming
data as long as you like until exit programming mode.
EGRESS BUTTON
PRESS ONCE
5) To program a new Master Code to replace the old one. See "Record A Master Code" stated at
"Location 01" for the details.
NOTE:
The keypad will set itself to normal operation mode 1 minute after power-up if the Egress Button is
not pressed and the DAP code is not keyed in. To set keypad back to power-up mode, repeat
procedures 1-4.
SYSTEM REFRESHING WITH "REFRESHING CODE" --- 9 9 9 9
The keypad can be refreshed by cleaning all the programmed old data and set it back to default
values except the Master Code.
REFRESHING CODE
NOTE:
a)
Make sure that system refreshing is really required before entering the refreshing code.
b)
Refreshing takes few minutes. The status LED (amber) keeps flashing during refreshing.
c)
The keypad is back to its default value after refreshing. Re-program of the desired values are
necessary.
and validate it with
DAP CODE
VALIDATION

. The Status LED is ON and the
VALIDATION

Advertisement

Table of Contents
loading