EGRESS DELAY , WARNING AND ALARM

LOCATION

(1)
(1) LOCATION

Key in Location
(2) CONFIGURATIONS OF THE EGRESS WARNING AND ALARM
Key in the number to enable 1 of the configurations described below:
--- Momentary Contact Mode without Warning -- (Default)
Press the Button once. No warning or alarm is given during Egress Delay.
Good for silent area. The people have to wait for the door open until the delay time reaches.
--- Momentary Contact Mode with Warning Beep
Press the Button once. The system gives Warning Beeps during the Egress Delay.
Good for the place required attention. The keypad beeps during the people are waiting for the
door open.
--- Holding Contact Mode without Warning
Press and hold the Button. No warning or alarm is given during the Egress Delay.
Good for the silent area. The people require to press & hold the button until the delay time
reaches for the door open.
--- Holding Contact Mode with Warning Beep
Press and hold the Button. The system gives Warning Beeps during Egress Delay.
Good for the place required attention. The keypad beeps while the button is kept pressed during
the people are waiting for the door open.
(3) EGRESS DELAY TIMER
--- No Delay – (Default)
Output 1 activates instantly (the door is released instantly) when the Egress Button is pressed.

--- Egress Delay Timing
Put a number of 1 to 99 into the box to enable the Egress Delay. The number is the time in second,
which starts to count when the Egress Button is pressed. Output 1 activates (the door is released)
when the delay time reaches.