D) Configuration of Output Modes
--
Installer Programming
Locations
Code of Duration
Validation
Comments
40
#
1 to 999
Output 1 in Momentary Mode from 1 to 999 seconds
41
#
Output 1 in Start / Stop Mode (toggle)
42
#
Output 1 in Start / Stop Mode (toggle) with accelerated code
50
#
1 to 999
Output 2 in Momentary Mode from 1 to 999 seconds
51
#
Output 2 in Start / Stop Mode (toggle)
52
#
Output 2 in Start / Stop Mode (toggle) with accelerated code
60
#
1 to 999
Output 3 in Momentary Mode from 1 to 999 seconds
61
#
Output 3 in Start / Stop Mode (toggle)
62
#
Output 3 in Start / Stop Mode (toggle) with accelerated code
E) Personal Safety
--
Installer Programming
Locations
No. of False Entry Validation Comments
70
#
71
#
72
#
5 to 10
76
#
00
F) Door Forced-Open Alarm
--
Installer Programming
Locations
Code of Functions Validation
Comments
80
1
#
Door Forced-Open Alarm is Enabled
80
0
#
Door Forced-Open Alarm is Disabled
G)
Output Activation Announcer
--
Installer Programming
Locations
Code of Functions Validation
Comments
81
1
#
1 second notifying beep is given to notify the person outside to open
the door when output relay is activated with an user code or egress
button. Good for the locking device that gives no sound when it
activates, such as a magnetic lock.
81
0
#
Notifying beep disabled and replaced by 2 short successful code entry
beeps for valid user codes
H) User Code Entry Mode (Auto or Manual)
Locations
Code of Functions Validation
Comments
82
1
#
Auto Entry Mode is selected.
required in code entry. The User Codes MUST be set in the same digit
length as the Master Code in Auto Entry Mode and the code length can
be 4-8 digits
82
0
#
Manual Entry Mode is selected.
required in code entry. The user codes can be 4-8 digits and they are
not required to be in the same length as the Master Code
NOTE:
In Single User Mode, no matter the selection is Auto or Manual mode, the Master Code and the User Code
MUST be set in the length of 4 digits.
After 10 successive false codes, the keypad locks during 30 seconds
After 10 successive false codes, the Duress output switches to ground
Selectable of a
fter 5 to 10 successive false codes, the keypad locks
during 15 minutes. The keypad can be reset to release locking with the
Master Code at any time during the locking period
Disappearance of all the above securities
--
Installer Programming
#
key that follows the user code is NOT
#
key that follows the user code is
6
2) BASIC WIRINGS FOR ALARM ARM-DISARM AND STAND ALONE DOOR LOCK
OUTPUT 1
N.C. C. N.O.
N.C. N.O.
OR
ELECTRIC
LOCK
1N4004
EGRESS BUTTON
(INSIDE THE HOUSE)
CONNECTION HARNESS
1 2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
F
The door lock function is exactly the same as like the Application Example (1) except the Green and Red LED
indications.
F
The Green and Red LEDs are used for Alarm Status indications, such as EXIT, Armed, Alarm Memory etc.
F
Relay Output 2 is used for Alarm Arm-Disarm Control. Please consult your alarm control panel manual for the
appropriate output contact and the operation mode for the control; such as N.O. or N.C. contact, and Momentary
or Start / Stop mode are required.
F
Connect the Tamper Switch to a 24 hour N.C. zone and the Duress output to a 24 hour N.O. zone for
tamperproof and emergency reporting.
F
Connection of "Output 3" to "Output 1 Inhibit" is optional. With this connection, the owner may use the User
Code 3 as authorization Code to stop the operation of the electric lock in the night time or after office hour to
prevent unauthorized access. Set output 3 in Start / Stop mode (Programming Option 61) for ON-OFF control.
The centre LED will change from flashing Green to Red while the operation of the electric lock is stopped.
F
The Yellow green wire is the common ground to link up the keypad and the alarm control panel to achieve the
logical functions.
F
Please also see the NOTE stated in Application Example (1) for the common information.
TERMINALS
( + ) ( ) -
EG
DOOR
SENS
IN
12-24V AC/DC
12V DC
POWER
SUPPLY
MORE EGRESS BUTTONS
N.O.
N.O.
CAN BE CONNECTED IN PARALLEL
ALARM CONTROL PANEL
N.O.
WHITE/ORANGE
DURESS -- TO A 24 HOUR N.O. ZONE
YELLOW GREEN
( )
-
COMMON GROUND OF KEYPAD AND ALARM SYSTEMS
PURPLE
N.C.
OUTPUT 2
ALARM ARM-DISARM CONTROL
BLUE
N.O.
* CONSULT YOUR ALARM INSTALLATION
WHITE/BROWN
COM.
MANUAL FOR N.C. OR N.O. FOR THE CONTROL
(+)
YELLOW
RED LED
LIGHT BLUE
( )
-
FOR ALARM STATUS INDICATION
(+)
GREEN
GREEN LED
GREY
( )
-
FOR ALARM STATUS INDICATION
BLACK
TAMPERPROOF
N.C.
RED
TO A 24 HOUR N.C. ZONE
15