NOTE:
1) Momentary Contact -- The Egress Delay starts to count when the egress button is momentarily
pressed. Output 1 activates automatically (door is released) when the delay time reaches.
2)
Holding Contact -- The user MUST hold the egress button in contact for the whole period of the
Egress Delay time until Output 1 activates. If the egress button is released before the end of the
Egress Delay, the timer will stop to count and reset.
For safety, it is necessary to put a sticker next to the egress button telling how to open the
door if "Holding Contact" is enabled.
Example: A sticker for an egress button that is programmed with "Holding Contact" of 5 seconds.
3) The Egress Delay does not affect the operation of the User Codes/Cards for Output 1. The User
s/Cards always give INSTANT action.
Code
(4) VALIDATION
Press
key once . Two-beeps confirms the entry
EXAMPLES:
Example 1: Set Egress Button in Momentary contact of 5 seconds with delay & warning beep
(a) Egress function programming, (b) Momentary contact with warning, (c) Delay time of 5 seconds
to release door, (d) Entry confirmation
Example 2: Set Egress Button in Holding contact of 10 seconds with warning beep
(a) Egress function programming, (b) Holding contact mode with warning, (c) Holding time of 10
seconds to release door, (d) Entry confirmation
Example 3: Set Egress Button in Momentary contact without delay (This is the default setting)
(a) Egress function programming, (b) Momentary contact without delay, (c) Release door instantly,
(d) Entry confirmation
Press & Hold The Button
5 Seconds Minimum
Until The Door Is Open
(a)
(b)
(c)
(a)
(b)
(a)
(b)
(d)
(c)
(d)
(c)
(d)


Advertisement