6. CONVERT THE CONTROL ELEMENTS FROM REMOTE TO MANUAL

6.1 REQUIRED TOOLS AND MATERIALS
Required tools and materials
Controls kit ICP
T10 Torx key or T10 Setup tool from the RWS-axle
8 mm bit
16 mm, 19 mm open end wrench
Torque wrench with a 2 mm hexagon and T10 Torx bit
Loctite 241 or Loctite 243
Degreaser
6.2 OVERVIEW CONTROLS KIT
1
2
3
4
5
6
7
8
1
fixing screw for the mode lever
2
mode lever
3
compression adjuster
4
compression nut
5
index wheel
9
6
O-ring
7
index pin
8
spring
9
cover