4-8 Physical Mounting

4-8-3 Bracket Mounting Points

The bracket included with the F3SS is designed to offer a wide range of mounting options and can be attached
either to the bottom of the emitter and receiver (allowing the widest range of adjustment) or directly to the back
cover of either unit.
Misalignment may increase reflective surface interference. Physical alignment of the emitter and receiver
should be performed carefully upon installation, and checked periodically thereafter.
(When tightened,
mounting screws
prevent T-nuts from
sliding) Slots for T-nuts
BOTTOM VIEW

4-8-4 Alignment

Two aids have been provided on the F3SS to assist with long-range alignment.
A "gunsight" device has been designed into the top of the emitter and receiver housing to aid in physical align-
ment.
Additionally, the receiver has an amber-color visible alignment indicator which provides the following informa-
tional.
If the amber light is:
Steady On
Flashing
Off
Note: Where used with mirrors it is recommended to use the optional laser alignment tool, F39-LLK, to ease
alignment.
WARNING
T-Nut
T-Nut
Slides In Slot
Gunsight
Figure 4-15 Mounting Bracket
Table 4-4 Alignment indicator light
Out of Alignment or beam blocked
Mounting Bracket
Washers
Mounting Screw
See Above
Detail
Mounting Screws (4)
REAR VIEW
This indicates:
Strong Signal
Weak Signal
4 Installation