20. OFFSET MEASUREMENT

20.5 Column Offset Measurement

Find distance and coordinates of the center of the column.
If circumscription point (P1) and two circumscription points (P2, P3) of a column
can be measured directly, the distance to the center of the column (P0),
coordinates and azimuth angle are calculated and displayed.
• The azimuth angle of the center of the column is 1/2 of total azimuth angle of
circumscription points (P2) and (P3).
PROCEDURE
1. Enter the instrument station data.
"13.1 Entering Instrument
Station Data and Azimuth
Angle"
2. Press [OFFSET] in page three of
OBS mode to display <Offset>.
3. Select "Offset Clum" in <Offset>.
136
Offset Clum