Torque Instructions
Torque Instructions
Instructions
Torque
Torque
Instructions
If fluid cover or manifold fasteners have been
loosened, it is important to torque them using the
following procedure to improve sealing.
NOTE: Fluid cover and manifold fasteners have a
NOTE:
NOTE:
thread-locking adhesive patch applied to the threads.
If this patch is excessively worn, the fasteners may
loosen during operation. Replace screws with new
ones or apply medium-strength (blue) thread locker
on threads.
NOTE: Always completely torque fluid covers before
NOTE:
NOTE:
torquing manifolds.
Torque sequence
sequence
Torque
Torque
sequence
Aluminum Pumps
Pumps
Aluminum
Aluminum
Pumps
1. Left/Right Fluid Covers
Torque bolts to 75–81 N•m (55-60
ft-lb)
SIDE VIEW
20
1. Start all fluid cover screws a few turns. Then, turn
2. Turn each screw by 1/2 turn or less working in a
3. Repeat for manifolds.
4. Check and tighten nuts and bolts (AA) holding
2. Manifolds
Torque bolts 15–28 N•m (1–8 to
11-21 ft-lb)
down each screw just until head contacts cover.
crisscross pattern to specified torque.
the manifold feet to the mounting brackets.
Torque bolts 75–81 N•m (9–16 to
55-60 ft-lb)
TOP/BOTTOM VIEW
859.0634