Torque Instructions

Torque
Torque
Torque Instructions
Instructions
Instructions
If fluid cover or manifold fasteners have been
loosened, it is important to torque them using the
following procedure to improve sealing.
NOTE:
NOTE: Fluid cover and manifold fasteners have a
NOTE:
thread-locking adhesive patch applied to the threads.
If this patch is excessively worn, the fasteners may
loosen during operation. Replace screws with new
ones or apply medium-strength (blue) thread locker
on threads.

Torque sequence

sequence
Torque
Torque
sequence
Aluminum
Aluminum Pumps
Aluminum
Pumps
Pumps
1. Left/Right Fluid Covers
Torque bolts to 22.6–23.7 N•m
(200-210 in-lb)
1
3
8
10
12
6
2
4
SIDE VIEW
Stainless
Stainless
Stainless Steel
Steel or or or Cast
Steel
Cast
Cast Iron
Iron Pumps
Iron
1. Left/Right Fluid Covers
Torque bolts to 22.6–23.7 N•m
(200-210 in-lb)
1
3
8
10
12
6
2
4
SIDE VIEW
22
All manuals and user guides at all-guides.com
2. Inlet Manifold
Torque bolts to 14.7–15.8 N•m
(130-140 in-lb)
16
5
11
9
7
13
BOTTOM VIEW
Pumps
Pumps
2. Inlet Manifold
Torque bolts to 22.6–23.7 N•m
(200-210 in-lb)
16
5
11
9
7
13
BOTTOM VIEW
NOTE: Always completely torque fluid covers before
NOTE:
NOTE:
torquing manifolds.
1. Start all fluid cover screws a few turns. Then, turn
down each screw just until head contacts cover.
2. Turn each screw by 1/2 turn or less working in a
crisscross pattern to specified torque.
3. Repeat for manifolds.
3. Outlet Manifold
Torque bolts to 14.7–15.8 N•m
(130-140 in-lb)
14
15
3. Outlet Manifold
Torque bolts to 22.6–23.7 N•m
(200-210 in-lb)
14
15
18
20
17
19
TOP VIEW
18
20
17
19
TOP VIEW