Technical Data
Mechanical data
Enclosure
Cover
Actuator
Ambient air temperature
Contact type
Mechanical life
Switching frequency
Assembly
Connection
Conductor cross-sections
Cable entrance
Weight
Installation position
Protection type
ID for safety engineering
B10d
Actuation
The push bolt actuator is mainly intended to be actuated along its axis.
Side actuation will considerably reduce switch life.
Standards
EU Conformity
Approvals
Notes
The degree of protection specified (IP code) applies only to a properly closed protective guard and the use of an equivalent cable gland with
adequate cable.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-10-24 and will not be removed in case of changes.
Thermoplastic, glass fibre reinforced
Thermoplastic, glass fibre reinforced
plunger (Thermoplastic)
-30 °C ... +80 °C
1 NC, 1 NO (Zb)
6
10 x 10
operating cycles
≤ 100 / min.
2 x M4 / 2 x M5 / 2 x M3 front mounting
4 screw connections (M3,5)
Solid: 0,5 ... 1,5 mm²
Litz wire with ferrules: 0,5 ... 1,5 mm²
2 x M16 x 1,5
≈ 0,08 kg
operator definable
IP65 acc. to IEC/EN 60529; DIN VDE 0470 T1
20 x 10
6
cycles
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
DIN EN ISO 13849-1
acc. to directive 2014/35/EU
CSA
A300, Q300
C
US
CCC
Page 2 of 2
6085103100 / 2620-16