ThyssenKrupp TW160 Operating Manual page 105

Table of Contents

Advertisement

Technical Data
Plastic bodied limit switch
Series BI2
Description BI2-U1Z W
Operating symbol
Operating diagram
Tolerance:
Operating Point ± 0,25 mm;
Operating force ± 10 %
On
Off
Electrical Data
Rated insulation voltage
Conv. thermal current
Rated operational voltage
acc. to
C
Utilization category
Direct opening action
Short-circuit protective device
Protection class
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-10-24 and will not be removed in case of changes.
U
400 V AC
i
I
10 A
the
U
240 V AC
e
CSA
U
300 V AC
US
e
AC15 U
/ I
240 V / 3 A
e
e
acc. to IEC/EN 60947-5-1, annex K
p
Fuse 10 A gG
II (totally insulated)
Page 1 of 2
Article number 6085103100
Fixed positioning with
e.g. fixing screw M5
according to the standard
DIN EN ISO 4762.
6085103100 / 2620-16