Daikin FTXA20A Service Manual page 97

Split stylish r32
Table of Contents

Advertisement

FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05
VDC
Com
DC–
W
Power module IPM2 for fan motor
1 Disconnect the fan motor connector from the main PCB.
2 Check the power module IPM2 in reference with the image and the table
below.
d
e
a U
b V
c W
d DC+
e DC–
INFORMATION
When measuring on the front of the main PCB, make sure to locally remove the
protective varnish with the test leads of the multi meter.
VDC
Com
U
DC+
V
DC+
W
DC+
DC–
U
DC–
V
DC–
W
Are the test results OK?
Yes
Ref
VDC
0.501 V
W
c
b
a
Ref
VDC
0.475 V
DC+
0.475 V
DC+
0.475 V
DC+
0.475 V
U
0.475 V
V
0.475 V
W
Action
Power modules are OK. Return to
"Checking
procedures" [
main PCB and continue with the next
procedure.
2
Components
|
Com
Ref
DC–
O.L
Com
Ref
U
O.L
V
O.L
W
O.L
DC–
O.L
DC–
O.L
DC–
O.L
4
 91] of the
Service manual
97