Daikin FTXA20A Service Manual page 64

Split stylish r32
Table of Contents

Advertisement

2
|
Components
To install the expansion valve coil with bracket
Service manual
64
a Expansion valve coil
b Pipe retention clip
c Pipe
2 Route the expansion valve coil harness towards the appropriate PCB.
3 Connect the expansion valve coil connector to the appropriate PCB.
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
4 Fix the expansion valve coil harness using new tie straps.
5 Install the insulation cap on the expansion valve coil (if applicable).
Is the problem solved?
Yes
No
1 Install the expansion valve coil on the expansion valve body.
INFORMATION
The expansion valve coil is equipped with a metal bracket. Fit the nipples of the
metal bracket into the notches of the expansion valve body.
CAUTION
Make sure to install the expansion valve coil in the correct position (orientation).
a
b
c
Action
No further actions required.
Return to
procedures" [
valve and continue with the next
procedure.
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
"2.3.1 Checking
4
 57] of the expansion
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents