Daikin FTXA20A Service Manual page 178

Split stylish r32
Table of Contents

Advertisement

5
|
Technical data
R2T
Y1S
e
e
S1PH
M1C
R3T
a Field piping (liquid: Ø6.4 mm flare connection)
b Field piping (gas: Ø12.7 mm flare connection)
c Stop valve (liquid)
d Stop valve (gas)
e Muffler
f Gas receiver
g Filter
h Muffler with filter
i Heat exchanger
j Accumulator
Service manual
178
RXA42~50A
i
M1F
j
INFORMATION
The diagrams shown in this manual may be incorrect due to changes/updates to the
unit. Correct diagrams are supplied with the unit and can also be found in the
technical data book.
R1T
Y1E
g
f
e
e
M1C Compressor
M1F Fan
R1T Thermistor (outdoor air)
R2T Thermistor (heat exchanger)
R3T Thermistor (compressor discharge)
S1PH High pressure switch
Y1E Electronic expansion valve
Y1S Solenoid valve (4‑way valve)
Cooling
Heating
h
c
e
d
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
a
b
Split Stylish R32
ESIE18-03D – 2021.05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents