To connect the electrical wiring to the indoor unit ....................... 42 To connect optional accessories (wired user interface, central user interface, etc.) ........... 43 9 Finishing the indoor unit installation Installer reference guide CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Daikin room air conditioner 4P518023-15P – 2023.05...
Page 3
To perform a test run using the wireless remote control ................50 12 Hand-over to the user 13 Disposal 14 Technical data 14.1 Wiring diagram................................53 14.1.1 Unified wiring diagram legend ........................53 15 Glossary CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
WARNING Make sure installation, servicing, maintenance, repair and applied materials follow the instructions from Daikin (including all documents listed in “Documentation set”) and, in addition, comply with applicable legislation and are performed by qualified persons only. In Europe and areas where IEC standards apply, EN/IEC 60335-2-40 is the applicable standard.
About the documentation Technical engineering data ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required).
Page 6
Example: " 1–3 Figure title" means "Figure 3 in chapter 1". Indicates a table title or a reference to it. Example: " 1–3 Table title" means "Table 3 in chapter 1". CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
WARNING Improper installation or attachment of equipment or accessories could result in electrical shock, short-circuit, leaks, fire or other damage to the equipment. ONLY use accessories, optional equipment and spare parts made or approved by Daikin unless otherwise specified. WARNING Make sure installation, testing and applied materials comply with applicable legislation (on top of the instructions described in the Daikin documentation).
WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation and are executed ONLY by authorised persons. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P –...
Page 9
Keep the pipework installation to a minimum. To determine the minimum floor area 1 Determine the total refrigerant charge in the system (= factory refrigerant charge additional refrigerant amount charged). CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Page 10
Total refrigerant charge in the system Minimum floor area (a) Ceiling-mounted unit (= Ceiling-mounted unit) (b) Wall-mounted unit (= Wall-mounted unit) (c) Floor-standing unit (= Floor-standing unit) CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Make sure refrigerant piping installation complies with applicable legislation. In Europe, EN378 is the applicable standard. NOTICE Make sure the field piping and connections are NOT subjected to stress. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
For the location of the terminals, see the wiring diagram. ▪ Do NOT touch electrical components with wet hands. ▪ Do NOT leave the unit unattended when the service cover is removed. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Page 13
MUST be as such that the current-carrying wires are tautened before the earth wire is in case the power supply is pulled loose from the stress relief. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Page 14
ON and OFF while the product is operating, attach a reversed phase protection circuit locally. Running the product in reversed phase can break the compressor and other parts. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Use flare nuts that are included with the unit. Using different flare nuts may cause refrigerant gas leakage. "8 Electrical installation" [ 39]) Electrical installation (see DANGER: RISK OF ELECTROCUTION WARNING ALWAYS use multicore cable for power supply cables. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Page 16
This could result in electrical shock or fire. WARNING Keep the interconnection wiring away from copper pipes without thermal insulation as such pipes will be very hot. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
"9.3 To fix the unit on the mounting plate" [ 45]. f Dry battery AAA.LR03 (alkaline) for the wireless remote control g Wireless remote control (user interface) holder h Wireless remote control (user interface) CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Page 18
Spare SSID sticker. Do NOT throw away the spare sticker. Keep it in a safe place in case it is needed in future (e.g. in case the front grille was replaced attach it to the new front grille). CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Condensation and water dripping might occur if the unit runs outside its operation range. 5.3 About the wireless LAN For detailed specifications, installation instructions, setting methods, FAQ, declaration of conformity and the latest version of this manual, visit app.daikineurope.com. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
About the unit INFORMATION: Declaration of conformity ▪ Daikin Industries Czech Republic s.r.o. declares that the radio equipment type inside of this unit is in compliance with Directive 2014/53/EU and S.I. 2017/1206: Radio Equipment Regulations 2017. ▪ This unit is considered as combined equipment according to the definition of Directive 2014/53/EU and S.I. 2017/1206: Radio Equipment Regulations 2017.
Page 21
About the unit INFORMATION Scan the QR code to download and install the ONECTA app on your mobile phone or tablet: CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
The sound pressure level is less than 70 dBA. ▪ Air flow. Make sure nothing blocks the air flow. ▪ Drainage. Make sure condensation water can be evacuated properly. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Page 23
(mm) Note: Make sure that there are no obstacles within 500 mm under the infrared signal receiver. They may influence reception performance of the wireless remote control. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
2 Open the panel locks located on the back side of the panel (1 on each side). a Panel lock 3 Push the right arm lightly to the right to disconnect the shaft from the shaft slot on the right side. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
4 Remove the flap by pushing it to the left side and towards you. 5 Remove the 2 screw covers using a long flat plate such as a ruler wrapped in a cloth and remove 2 screws. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
1 Remove 1 screw from the electrical wiring box. 2 Open the electrical wiring box cover by pulling it to the front. 3 Remove the electrical wiring box cover from the 2 rear hooks. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
4 Finish the installation by securing the mounting plate on the wall using M4×25L screws (field supply). INFORMATION The removed pipe port cover can be kept in the mounting plate pocket. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Wall embedded pipe b Putty c Wall hole cover 4 After completing wiring, refrigerant piping and drain piping, do NOT forget to seal the gap with putty. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
NOTICE ▪ Install the drain hose with a downward slope. ▪ Traps are NOT permitted. ▪ Do NOT put the end of the hose in water. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
1 Attach the drain hose with adhesive vinyl tape to the bottom of the refrigerant pipes. 2 Wrap the drain hose and the refrigerant pipes together using insulation tape. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Insulation fixing screw b Drain hose 4 Attach the drain hose to the refrigerant piping bottom side using adhesive vinyl tape. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
6.4.4 To check for water leaks 1 Remove the air filters. 2 Gradually pour approximately 1 l of water in the drain pan, and check for water leaks. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Connecting the refrigerant piping to the outdoor unit ▪ Insulating the refrigerant piping ▪ Keeping in mind the guidelines for: Pipe bending Flaring pipe ends Using the stop valves CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Use caution when passing copper tubes through walls (see figure below). Unit Installation period Protection method Outdoor unit >1 month Pinch the pipe <1 month Pinch or tape the pipe Indoor unit Regardless of the period CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
1 Cut the pipe end with a pipe cutter. 2 Remove burrs with the cut surface facing down so that the chips do NOT enter the pipe. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Test leaks using a pressure of at least 0.25 times the maximum working pressure (see "PS High" on the unit nameplate). If a leak is detected 1 Recover the refrigerant, repair the joint, and repeat the test. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
ALWAYS use multicore cable for power supply cables. INFORMATION Also read the precautions and requirements in the "2 General safety precautions" [ 7]. INFORMATION Also read "8.1.3 Specifications of standard wiring components" [ 41]. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
To prepare stranded conductor wire for installation Method 1: Twisting conductor 1 Strip insulation (20 mm) from the wires. 2 Slightly twist the end of the conductor to create a "solid-like" connection. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
8.1.3 Specifications of standard wiring components Component Interconnection cable Voltage 220~240 V (indoor↔outdoor) Wire size Only use harmonized wire providing double insulation and suitable for applicable voltage 4-core cable Minimum 1.5 mm² CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Note: In case the interconnection cable was stripped in advance, cover the ends with insulating tape. 4 Bend the end of the cable up. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
S21 connector 3 Put the electrical wiring box cover back and pull the wire harness around it as shown in the figure above. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
1 Shape the refrigerant pipes along the pipe path marking on the mounting plate. a Drain hose b Caulk this hole with putty or caulking material c Adhesive vinyl tape d Insulation tape e Mounting plate (accessory) CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
4 Insert the wire harness back into the connector and secure it with the wire clamp. 5 Close the front panel. Refer to "9.4.4 To close the front panel" [ 46]. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
1 Open the front panel and turn the flap up. 2 Install both screw covers (1 on each side). 3 Return flap to its original position and close the front panel. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Factory setting After cutting with nippers INFORMATION If the setting could NOT be completed while the operation lamp was blinking, repeat the setting process from the beginning. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Page 48
Configuration 7 When the setting is complete, keep pressed for at least 5 seconds. Result: The user interface will return to the previous screen. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
11 Commissioning NOTICE General commissioning checklist. Next to the commissioning instructions in this chapter, a general commissioning checklist is also available on the Daikin Business Portal (authentication required). The general commissioning checklist is complementary to the instructions in this chapter and can be used as a guideline and reporting template during commissioning and hand-over to the user.
2 Press simultaneously. 3 Press , select and press Result: Test run operation will stop automatically after about 30 minutes. 4 To stop operation sooner, press CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Explain the user how to properly operate the system and what to do in case of problems. ▪ Show the user what to do for the maintenance of the unit. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Technical data 14 Technical data ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). 14.1 Wiring diagram The wiring diagram is delivered with the unit, located on the inner right side of the indoor unit front grille.
Page 54
Number of passes through ferrite core Pulse-amplitude modulation PCB* Printed circuit board Power module Switching power supply PTC* PTC thermistor Insulated gate bipolar transistor (IGBT) Circuit breaker CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S) Installer reference guide Daikin room air conditioner 4P518023-15P – 2023.05...
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
Page 60
4P518023-15P 2023.05 Verantwortung für Energie und Umwelt...