Daikin FTXA50B Manuals
Manuals and User Guides for Daikin FTXA50B. We have
1
Daikin FTXA50B manual available for free PDF download: Service Manual
Daikin FTXA50B Service Manual (192 pages)
Split Stylish R32
Brand:
Daikin
| Category:
Air Conditioner
| Size: 9.09 MB
Table of Contents
Table of Contents
4
1 Troubleshooting
7
To Display the Error Code on the User Interface
7
To Reset the Error Code Via Remote Controller
7
To Reset the Error Code Via Outdoor Unit
7
To Perform a Test Run
7
To Perform a Test Run Using the User Interface
8
Error Based Troubleshooting
8
A1-00 - PCB Abnormality
8
A5-00 - Outdoor Unit: High Pressure Peak Cut / Freeze Protection Problem
9
A6-00 - Indoor Unit Fan Motor Abnormality
9
Streamer Unit Abnormality
10
C4-00 - Heat Exchanger Temperature Sensor Problem
10
C9-00 - Room Thermistor Abnormality
11
Humidity Sensor Abnormality
11
Intelligent Thermal Sensor Abnormality
12
E1-00 - Outdoor Unit: PCB Defect
12
E3-00 - Outdoor Unit: Actuation of High Pressure Switch
13
E5-00 - Outdoor Unit: Overheat of Inverter Compressor Motor
14
E6-00 - Outdoor Unit: Compressor Startup Defect
15
E7-00 - Outdoor Unit: Malfunction of Outdoor Unit Fan Motor
16
E8-00 - Outdoor Unit: Power Input Overvoltage
16
Outdoor Unit: Cool/Heat Switchover Problem
17
F3-00 - Outdoor Unit: Malfunction of Discharge Pipe Temperature
18
F6-00 - Outdoor Unit: Abnormal High Pressure in Cooling
19
F8-00 - System Shutdown Due to Compressor Internal Temperature Abnormality
20
H0-00 - Outdoor Unit: Voltage/Current Sensor Problem
20
H3-00 - Outdoor Unit: Malfunction of High Pressure Switch
21
H6-00 - Outdoor Unit: Malfunction of Position Detection Sensor
22
H8-00 - Outdoor Unit: Malfunction of Compressor Input System
23
H9-00 - Outdoor Unit: Malfunction of Outdoor Air Thermistor
23
J3-00 - Outdoor Unit: Malfunction of Discharge Pipe Thermistor
24
J6-00 - Outdoor Unit: Malfunction of Heat Exchanger Thermistor
24
L3-00 - Outdoor Unit: Electrical Box Temperature Rise Problem
24
L4-00 - Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise
25
L5-00 - Outdoor Unit: Inverter Instantaneous Overcurrent
26
P4-00 - Outdoor Unit: Malfunction of Radiating Fin Temperature Sensor
27
U0-00 - Outdoor Unit: Shortage of Refrigerant
27
U2-00 - Outdoor Unit: Defect of Power Supply Voltage
28
U4-00 - Indoor/Outdoor Unit Communication Problem
29
U5-00 - User Interface Communication Problem
30
Indoor Unit, Outdoor Unit Mismatching Problem
30
Symptom Based Troubleshooting
32
Operation Does Not Start
32
Operation Sometimes Stops
32
Operation Starts but the Unit Does Not Cool/Heat
33
Operating Noise and Vibrations
34
Abnormal High Pressure
35
Abnormal Low Pressure
36
Indoor Fan Starts Operating but the Compressor Does Not Operate
37
Operation Starts and the Unit Stops Immediately
38
Operation Stops, Unit Cannot Start for a While
38
Unit Discharges White Mist
39
Humidifying Problem
39
Swing Flap Does Not Operate
39
2 Components
40
4-Way Valve
40
Checking Procedures
40
Repair Procedures
43
Compressor
46
Checking Procedures
46
Repair Procedures
52
Expansion Valve
57
Checking Procedures
57
Repair Procedures
60
Front Panel Motor
65
Checking Procedures
65
Repair Procedures
66
High Pressure Switch
67
Checking Procedures
67
Repair Procedures
69
Humidity Sensor
70
Checking Procedures
70
Repair Procedures
71
Indoor Unit Fan Motor
73
Checking Procedures
73
Repair Procedures
73
Indoor Unit Main PCB
75
Checking Procedures
75
Repair Procedures
78
Indoor Unit Power PCB
81
Checking Procedures
81
Repair Procedures
84
Intelligent Thermal Sensor
88
Checking Procedures
88
Repair Procedures
88
Inverter PCB
89
Checking Procedures
89
Repair Procedures
91
Main PCB
91
Class 20~35 Units
91
Class 42~50 Units
99
Outdoor Unit Fan Motor
111
RXA20~35A3+5 Units
111
RXA20~35A2 + Class 42~50 Units
115
Plate Work
120
Outdoor Unit
120
Indoor Unit
126
Reactor
132
Checking Procedures
132
Repair Procedures
136
Streamer Unit
137
Checking Procedures
137
Repair Procedures
137
Swing Flap Motor
138
Main Swing Flap Motor
138
Secondary Swing Flap Motor
140
Swing Raster Motor
143
Checking Procedures
143
Repair Procedures
144
Thermistors
144
Refrigerant Side Thermistors
144
Other Thermistors
151
Wifi Control PCB
153
Checking Procedures
153
Repair Procedures
154
3 Third Party Components
156
Electrical Circuit
156
Checking Procedures
156
Repair Procedures
157
Refrigerant Circuit
158
Checking Procedures
158
Repair Procedures
162
External Factors
165
Checking Procedures
165
4 Maintenance
167
To Clean the Outdoor Unit Heat Exchanger
167
To Clean the Indoor Unit Heat Exchanger
167
To Clean the Indoor Unit Heat Exchanger in Extreme Condition
167
To Clean the Air Filters
168
5 Technical Data
170
Detailed Information Setting Mode
170
Detailed Information Setting Mode: Indoor Unit
170
Detailed Information Setting Mode: Outdoor Unit
170
Detailed Information Setting Mode: Remote Controller
170
Wiring Diagram
171
Wiring Diagram: Indoor Unit
171
Wiring Diagram: Outdoor Unit
173
Piping Diagram
176
Piping Diagram: Indoor Unit
176
Piping Diagram: Outdoor Unit
177
Component Overview
180
Component Overview: Indoor Unit
180
Component Overview: Outdoor Unit
182
Field Information Report
185
Service Tools
188
Field Settings
189
To Control Heating Only Mode
189
To Adjust Target Set Temperature in Heating Operation
189
To Control the Indoor Unit Fan During Thermostat off in Cooling
190
To Change Auto Restart on to off
190
To Control Cooling Mode Only
190
To Reduce Maximum Sound Levels
191
Advertisement
Advertisement
Related Products
Daikin FTXA50B2V1BS
Daikin FTXA50B2V1BT
Daikin FTXA50B2V1BB
Daikin FTXA50BB
Daikin FTXA50BS
Daikin FTXA50BT
Daikin FTXA50A2V1BS
Daikin FTXA50AW
Daikin FTXA50AS
Daikin FTXA50AT
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL