Measuring points
d
a L803
b L804
c Measuring point
d Measuring point
Is the resistance measurement correct? Action
Yes
No
4 Measure the inductance of the reactor using an LCR meter.
Result: The inductance MUST be 80~100 µH.
a L803
b L803 measuring point
c L804
d L804 measuring point
Is the inductance measurement
correct?
Yes
No
Class 42~50 units
1 Check that the reactors are firmly installed on the main PCB.
Resistance
68~102 mΩ
c
a
d
c
b
d
c
d
c
d
Proceed with the next step.
Replace the reactor, see
procedures" [
b
a
d
c
b
d
Action
Return to the troubleshooting of the
specific error and continue with the
next step.
Replace the reactor, see
procedures" [
2
Components
|
"2.15.2 Repair
4
 136].
"2.15.2 Repair
4
 136].