Daikin FTXA20A Service Manual page 152

Split stylish r32
Table of Contents

Advertisement

2
|
Components
Service manual
152
T °C
T °C
–9
106.03
21
–8
100.41
22
–7
95.14
23
–6
90.17
24
–5
85.49
25
–4
81.08
26
–3
76.93
27
–2
73.01
28
–1
69.32
29
0
65.84
30
1
62.54
31
2
59.43
32
3
56.49
33
4
53.71
34
5
51.09
35
6
48.61
36
7
46.26
37
8
44.05
38
9
41.95
39
4 Measure the resistance between the appropriate connection points of the
thermistor.
5 Check that the measured resistance value matches the resistance determined
through the measured temperature (earlier step in the procedure). E.g:
▪ Measured temperature with contact thermometer: 23.1°C,
▪ Resistance value determined through temperature (using the thermistor
table A):
Resistance at 20°C: 24.3 kΩ,
Resistance at 25°C: 19.4 kΩ,
▪ Measure resistance between pin 1‑2:
Measured resistance: 21.86 kΩ,
▪ Measured resistance value is inside the range. Thermistor passes the check.
INFORMATION
All thermistors have a resistance tolerance of 3%.
Does the measured resistance of the
thermistor match with the
temperature determined resistance?
Yes
No
T °C
23.91
51
6.91
22.85
52
6.65
21.85
53
6.41
20.90
54
6.65
20.00
55
6.41
19.14
56
6.18
18.32
57
5.95
17.54
58
5.74
16.80
59
5.14
16.10
60
4.87
15.43
61
4.70
14.79
62
4.54
14.18
63
4.38
13.59
64
4.23
13.04
65
4.08
12.51
66
3.94
12.01
67
3.81
11.52
68
3.68
11.06
69
3.56
Action
Thermistor is OK. Return to the
troubleshooting of the specific error
and continue with the next procedure.
Replace the specific PCB, see
"2 Components" [
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
T °C
4
 40].