Clearances To Combustibles; Alcove Clearances - Enviro Mini 2 Operator's Manual

Table of Contents

Advertisement

c
c
LearanceS to
ombuStIbLeS
IMPORTANT: The P3 must have a Hearth Pad when installing the unit on a combustible floor. The included
hearth pad meet all the requirement of a proper hearth pad. If you do not use the included hearth pad a certified
non combustible Hearth Pad with a minimum R Value of at least 0.84 must be placed underneath the unit and
extend six inches in front of the unit measured from the glass. If the P3 is installed on carpet the use of a solid non
combustible Hearth Pad must be used under leveling legs.
Back Wall 4in (10cm)
Hearth Pad 6in (15cm)
Figure 5: Minimum Install Clearances
a
c
:
Lcove
LearanceS
The unit may be installed in an alcove if desired.
These minimum clearances to combustibles must
be maintained at all times. Be sure to leave room
for servicing, routine cleaning, and maintenance.
These are inside dimensions.
Minimum Alcove Width
Minimum Alcove Height
Minimum Alcove Depth
10
Installation
:
36 inches (91.5 cm)
48 inches (122 cm)
30 inches (76 cm)
These dimensions are minimum clearances but it is
recommended that you ensure sufficient room for servicing,
routine cleaning and maintenance.
A. Side wall to unit
B. Back wall to unit
C. Back wall to Chimney Connector
D. Corner to unit
E. Glass to Hearth Pad
(91.5 cm)
30in
(76 cm)
48in
(122 cm)
Figure 6: Minimum Alcove Clearances
8 inches
5.5 inches (14 cm)
4in inches (10cm)
3 inches
6 inches
36in
(20 cm)
(7.5 cm)
(15 cm)