Installation; Appliance Dimensions And Specifications - Enviro Mini 2 Operator's Manual

Table of Contents

Advertisement

D
W
L
eciDing
HeRe to
1. Check clearances to combustibles.
2. Do not obtain combustion air from an attic, garage or any unventilated space.
Combustion air may be obtained from a ventilated crawlspace.
3. Do not install the stove in a bedroom.
4. You can vent the stove through an exterior wall behind the unit or connect it to
an existing masonry or metal wood stove chimney (must be lined if the chimney
is over 6" (15 cm) diameter, or over 28 inches² (180 cm²) cross sectional area).
An interior vent can be used with approved pipe passing through the ceiling
and roof.
5. Locate the stove in a large and open room that is centrally located in the house.
This will optimize heat circulation.
6. The power cord is 8 feet (2.43 m) long and may require a grounded extension
cord to reach the nearest electrical outlet.
a
D
ppLiance
imenSionS anD

Installation

p
a
ocate youR
eLLet
ppLiance
S
:
pecificationS
15
1
/
"
4
(386 mm)
17
7
/
"
8
(455 mm)
17
1
/
"
2
(444 mm)
19
3
/
"
4
(503 mm)
Figure 10: Dimensions of Mini.
:
Weight (with full hopper): 238 lb (108 Kg)
Hopper Capacity: up to 48 lb (21.8 Kg)
Voltage: 110 - 120 V
Max Current: 4.1 Amps
Consumption on High: 3.1 lb/hr (1.4 Kg/hr)*
Consumption on Low: 1.3 lb/hr (0.6 Kg/hr)*
(Note: Consumption will vary with the type of
fuel used.)
19"
(483 mm)
34
1
/
"
8
(868 mm)
19
1
/
"
2
(496 mm)
24
7
/
"
8
(632 mm)
AUGER
MODE
AUTO/OFF
HIGH/LOW
MANUAL
FEED RATE
HEAT LEVEL
TRIM
COMBUSTION
BLOWER TRIM
ROOM AIR
ON/OFF
FAN ON/OFF
13

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

P3-2

Table of Contents