Operating Instructions
o
y
p
peratIng
our
eLLet
PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly
against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
TO START: Press the Power button. The stove will turn on. The LED beside the Power button will flash
to indicate a start-up cycle. The Heat Level is shown on the LED display, you can change the Heat Level
and mode but these adjustments will not take affect until the start-up cycle is complete. If this is the first
time the unit has been started or the unit has run out of fuel, the auger will need to be primed. You may
need restart the unit if an E3 error occurs, to do this just press the Power button again. Once you see
pellets start to drop the auger is primed.
TO OPERATE: When a fire has been established, the Power LED will turn solid (after approximately 10
- 15 minutes) and the current settings will now take affect.
The convection blower (room air blower) will turn on once the start-up cycle is complete. The speed of
this blower is automatically controlled and is based off the heat level setting.
t
y
p
urnIng
our
eLLet
To turn off your Pellet stove just press the Power button. This will not shut off the stove instantly, it will
go intoa shut down cycle and take approximately 5 minutes for the fire to burn out. The fans will stay
running until the unit has cooled sufficiently.
DO NOT unplug unit while Combustion fan is running.
Unplugging may cause smoke to be released into the home.
D
S
-u
:
amper
et
p
THE SLIDER / DAMPER HAS BEEN SET AT THE FACTORY. This is used to regulate the airflow
through the pellet stove. The slider damper knob is located on the left cab side (see Figure 23).
The slider damper factory setting has been set for peak efficiency operation (see Figure 24).
If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the
Slider Damper may need to be adjusted by a qualified
technician only. Contact your local dealer.
For troubleshooting purposes the firebox vacuum
pressure may need to be confirmed. This should be
done only on a hot stove (operating for thirty (30)
minutes or more) by placing a Magnahelic Pressure
Gauge in the firebox. The reading can be taken from
the ⅛" (3 mm) hole located in the front of the firebox
under the door (see Figure 25). The factory setting
should read approximately 0.06 inches of water
column on the high fire setting.
S
:
tove
S
o
:
tove
ff
NEVER unplug a unit that is running!
Figure 23: Slider/Damper Adjustment
Damper
21