FX2N-64CL-M CC-Link/LT Master Block
11.2
System configuration
Main unit
FX
X000 to X017
Y000 to Y017
• In the case of system configuration above, twelve connectors for connection cable are
needed.
*1 The dedicated power supply is also available.
Master block
-32MR
FX
-64CL-M
2N
2N
Terminating
resistor
Remote station (station No.1)
CL1XY8-DR1B2
X020 to X023
Y020 to Y023
*1
General-purpose
power supply
Power adapter
24V DC
Remote station (station No. 2)
CL1XY8-DR1B2
X024 to X027
Y024 to Y027