ter). Anchor the ropes or secure them to the shoreline
so the ropes are free of slack, but not tight. To prevent
twisting of the unit due to torque, you should place
the anchor at least 3m from the fl oat for each meter of
depth (Ex. A 3m deep pond would require an anchor
9m horizontally from the fl oat.) For ease of removal,
you may choose to keep at least one anchor within
reach from shore, just below the water's surface.
Correct Anchoring
Incorrect Anchoring
STEP TWO (ALTERNATE INSTALLATION)
In ponds where the water level fl uctuates signifi cantly,
you may need to suspend a small weight (30cm of
2.54cm galvanize pipe works well) at the mid-point of
the rope to take up any slack as the water level drops.
The weight should be light enough so the Unit can rise
as the water level rises. This can also help hide ropes
by sinking them further below the surface.
Normal Water level
Anchor Rope
Secondary Weight
Low Water Level
High Water Level
STEP THREE
At this time the Fountain is ready for operation. The
unit can now be connected to the electrical circuit
(fi xed wiring) with a plug or direct wire connection.
The circuit must be provided with a disconnect switch,
short circuit, and ground fault protection (RCD).
Refer to unit specs for voltage and amperage ratings.
Also, the motor name plate lists the unit's electrical
Kasco Power
Control Box
Power Cord
ratings. Electrical installation must follow local and
national electrical codes and should be installed by a
professional.

Maintenance Recommendations

Under No Circumstances should anyone enter
the water while a unit is operating. Turn Off and Dis-
connect electrical power prior to any Maintenance or
Servicing
RCD (Residual Current Device) or GFCI are a safety
feature that can also alert you to electrical leaks in the
equipment. It is extremely important to test the RCD
upon installation, each reinstallation, and monthly
thereafter to ensure proper operation. If you have re-
peat, consistent trips on your ground fault (RCD), the
equipment should be disconnected and removed from
the water. The power cord should be inspected for
damage and you should call a Kasco Marine distribu-
tor or representative for further instructions.
If the supply cord becomes damaged, it must be
replaced by an authorized service center, or similarly
qualifi ed persons in order to avoid a hazard.
OBSERVATION: Operating equipment should be
observed on a regular basis (daily, if possible) for any
reduction or variation in performance. If a change in
performance is observed, the equipment should be dis-
connected from power and inspected for any material
that may have clogged the system or wrapped around
the shaft of the motor, especially plastic bags and fi sh-
ing line. Even though Kasco Fountains are among the
most clog-resistant on the market, it is impossible to
protect against all items that can clog equipment and
still maintain a fl ow of water. These materials can
be very damaging to the equipment under continued
operation and must be removed as soon as possible.
ALWAYS DISCONNECT POWER TO THE UNIT
BEFORE ATTEMPTING TO REMOVE CLOGS.
WINTER STORAGE: In regions where there is sig-
nifi cant freezing in the wintertime, Fountains should
be removed from the water to protect them from the
expansion pressure of the ice. Storage over winter is
11