To Add Two Mpb96 Boards - Nortel 1002rp Maintenance And Diagnostics

Callpilot
Table of Contents

Advertisement

Upgrading to High Capacity
Upgrading to High Capacity: M1/CS1000 switch connectivity

To add two MPB96 boards

1
Courtesy stop all CallPilot channels.
2
Power down the server and all peripheral devices.
3
Disconnect the following cables:
a. power cable
b. peripheral device cable
c. DS30X cables
4
Remove the server cover.
For instructions on removing the server cover, see "Removing the
front bezel and server cover" on page 110.
5
Disconnect the CT Bus cable (if present).
6
Ensure that there is an existing MPB96 board in PCI slot 3 (this is
standard for a 96-channel configuration).
7
Plug the first additional MPB96 board into PCI slot 6.
8
Plug the second additional MPB96 board into PCI slot 9.
9
Connect the 7-drop CT Bus cable to the MPB96 boards; the
connectors of the CT Bus cable must connect to the three MPB96
boards in slots 3, 6, and 9.
Note: There should be no dangling connectors at either end of the
CT Bus cable.
10
Replace the server cover.
11
Replace the front bezel and lock it.
12
Reconnect the peripheral device and power cables.
13
Reconnect the DS30X cable to the faceplate of the MPB96 board.
182
Standard 1.11
CallPilot

Advertisement

Table of Contents
loading