8-THEORY OF OPERATION

8.1 Description of the Working Cycle
After having closed the top fl aps of the carton,
the operator pushes it under the top infeed end
in order to avoid the opening of the top fl aps.
Further pushing causes the two top and bottom
belts to drive the box through the taping heads
which automatically seal the top and bottom seams.
The carton is then expelled on the exit conveyor.
8.2 Definition of Running Mode
The case sealer 700r3 has only one (automatic)
operating mode with:
- The EMERGENCY STOP BUTTON unlocked
(Figure 8-1)
- The main start switch "ON" (I)
(Figure 8-2)

8.3.1 Normal Stop Procedure

When the main switch is turned OFF (O), the
machine stops immediately at any point of the
working cycle. The same thing happens in case
of electrical failure or when the machine is
disconnected from the mains.

8.3.2 Emergency Stop

The LATCHING EMERGENCY STOP BUTTON
is located on the top center of the machine
(Figure 8-1).
700r3-NA
Figure 8-1
Figure 8-2
Figure 8-3
32
E-Stop Location
Belt
Direction