7-INSTALLATION (continued)
Machine Setup (continued)
4. Pneumatic connection.
a.
Read and remove safety tag from pneumatic
"On/Off" valve.
b.
Connect the main air supply line to the
inlet side of the on/off valve using the
barbed fi tting and hose clamp provided
(See Figure 7-7B).
The customer supplied air hose (8mm [5/16 inch]
ID) must be clamped tightly to the barbed fi tting.
If another type of connector is desired, the
barbed fi tting can be removed and replaced with
the desired 1/4-18 NPT threaded connector.
Always turn the air valve "Off" when the air
supply line is being connected or disconnected.
5. Turn the air supply on be turning the air on/off
valve to SUP (On).
6. Raise and latch upper drive assembly in full
"Up" position.
WARNING
• To reduce the risk associated with
mechanical and electrical hazards:
− Allow only properly trained and qualifi ed
personnel to operate and/or service this
equipment
WARNING
To reduce the risk associated with
impact hazards:
− Always use appropriate supporting
means when working under the upper
drive assembly
700r3-NA
Important – Use care when working with
compressed air.
The case sealer requires a 5 bar gauge
pressure 110 litre/min [70 PSIG], @21°C, 1.01 bar
[3.75 SCFM] compressed air supply. As shown in
Figure 7-14, an on/off valve, pressure regulator,
and fi lter are provided to service the air supply.
Note – A precision regulator is used to balance the
top drive assembly. Due to the self relieving
feature of this regulator a small amount of air
will continually vent to the atmosphere.
This is normal and amounts to approximately
3 litre/min. [0.1 SCFM].
Note – The air valve has provisions for Lockout/
Tagout according to plant regulations.
Note – Read "Operation – Mechanical Latch"
before raising and latching the
upper drive assembly.
21
2012 January

Advertisement

Table of Contents
loading

Table of Contents