Preparing for installation

Unpacking
Unpack the device and inspect it to ensure that it has not been damaged during transport.
The Q-10 / Q-10 POI is shipped with:
1 x TRUE1 power input connector, 2 m / 78 in. (standard only). In POI versions, it is supplied with a bare end power cable.
Two Omega brackets with 1/4-turn fasteners (standard only).
1 x Spanner with magnet (POI only).
6 x M-10 screws (POI Only).
Safety information leaflet.
Location / application
The standard fixture is IP65-rated and is designed for both indoor and outdoor events. This means that it is protected from:
Dust, to the degree that dust cannot enter the fixture in sufficient quantities as to interfere with its operation.
Lower pressure water jets from any direction.
The POI fixture is IP66-rated and designed for use in outdoor installations. This means that it is protected from:
Dust, to the degree that dust cannot enter the device in sufficient quantities as to interfere with its operation.
High pressure water jets from any direction.
When selecting a location for the device, ensure that:
It is situated away from public thoroughfares and protected from contact with people.
It has adequate ventilation.
It is not immersed in water.
When using standard fixtures outdoors or in wet locations, ensure that:
For wireless DMX or standalone operation, the protective cover is securely mounted in any unused DMX connectors in
order to ensure the IP-rating.
For cabled DMX operation, the DMX out of the last fixture is terminated with a 120 ohm-resistor between pin 2 and 3
(according to the RS485 standard), and the DMX out is properly sealed, in accordance with the ingress protection (IP)
requirements. Note that a maximum of 32 fixtures can be connected to the same DMX link.
Transportation
Always use the supplied packaging or suitable flight case for transportation and storage.
Never carry the fixture by connected cables or wires; use the handle.

Installing / rigging the Q-10 Series

All SGM luminaries have locking points in the base for installation and rigging. In both
standard and POI fixtures, the distance between the points from center to center is
always 106 mm.
While the base of the standard fixtures include 1/4 turn fasteners camlocks to mount the
omega brackets, the POI products come with M-10 nuts for M-10 screws.
The standard Q-10 may be installed in any orientation and it might take up to three
omega brackets per fixture. Always use a minimum of two omega brackets to rig the
fixture and lock the bracket with the 1/4-turn fasteners.
PLEASE NOTE!!
The 1/4-turn fasteners are only locked when turned fully clockwise.
NOTE: In POI fixtures, a customized bracket may have to be used to install the fixtures. See more about "Installation and
rigging of the Q-10 POI" on page 17.
106 mm
[ 4,2in ]
Ø 18 mm
[ 0,7in ]
Figure 2: Q-10 Series locking points