Tilt Lock; Connecting Ac Power - SGM Q Series User Manual

Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

Tilt Lock

The Q-10 can be tilted from 0° - 120°.
In standard versions, there is no need for any special tools to adjust the tilt angle.
Take the following steps for adjusting the tilt in standard Q-10:
1. Loosen the both tilt screws (one on each side) by turning them counter-clockwise.
2. Adjust the tilt to the desired angle and hold it.
3. Lock the position by re-tightening both tilt lock knobs clockwise.
If you feel resistance when tilting the fixture, you might not have loosened the tilt lock knobs enough.
CAUTION!!
If the fixture has been operating, always allow it to cool for 15 minutes before handling.
Exterior surface temperature after 5 min. operation = 45 °C (113 °F). Steady state = 68 °C (154 °F).
Angle indicator
The Q-10 comes with a scale function, which eases the adjustment to the tilt desired.
The angle indicator in the wheel shows the current angle of inclination.
NOTE: In POI versions, SGM provides a POI Spanner with a pig-nose key for tilt adjustment. Either use the large or the small
pig-nose key, depending on the type of fixture. See "POI Tilt lock" on page 17 to know more about the tilt lock in Q-10 POI.

Connecting AC power

The fixture must be grounded/
The Q-10 Series can operate on any 100–277 V, 50/60 Hz AC mains power supply.
earthed and be able to be isolated
from AC power. The AC power
Connect a Q-10 standard to AC power using the supplied cable with a IP-rated power, or similar with
supply must incorporate a fuse or
a maximum of 20 A, to ensure the correct ingress protection (IP-rating).
curcuit breaker for fault protection.
The fixture must be grounded/earthed and able to be isolated from AC power. The AC power supply
must incorporate a fuse or circuit breaker for fault protection.
The power cable color coding is given in figure 8:
The fixture must be grounded/
earthed and be able to be isolated
Connect the black wire to live.
from AC power. The AC power
Connect the white wire to neutral.
supply must incorporate a fuse or
Connect the green/yellow wire to ground (earth).
circuit breaker for fault protection.
For a temporary outdoor installation, the mains cable must be
fitted with a grounded connector intended for exterior use. For
permanent installations, have a qualified electrician to wire the mains cable directly to a suitable branch circuit. The junction's ingress
protection (IP) rating must be suitable for the location. Always use a junction box with a proper IP class suitable for the environment.
When installing standard type C circuit breakers, there will be no limitations due to the fixture in-rush current.
For assistance with alternative configurations, contact your SGM representative.
NOTE: In POI versions, SGM supplies a bare end power cable. Connect the fixture to power by mounting a power connector
to the bare end mains cable. Please refer to "Connecting DMX and AC power in POI" on page 17.
After connecting the Q-10 to power, run the on-board test by selecting TEST → AUTOMATED TEST in the menu, to ensure that the
fixture and each LED are functioning correctly. POI versions have to be tested through RDM.
PLEASE NOTE!
The protective caps must be securely mounted on any unused DMX connectors, in order to maintain the ingress protection (IP-rating).
CAUTION!!
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage.
Wire
Color
Black
White
green/yellow
Wire
Symbol
Conductor
L
live
N
neutral
or
ground (earth)
Color
Symbol
Black
L
White
N
green/yellow
Figure 8: Connecting AC Power
Pitch angle
indicator
Figure 6: Tilt lock
Figure 7: Q-10 Power cable
Conductor
live
neutral
or
ground (earth)
9