General
The General section of the Device Information page displays the name of the
selected device, its firmware version, the FPGA (Field-Programmable-Gate-
Array), video driver and information about its network configuration.
Note: The AP GUI version presents the same information as the Browser
version. Scroll through the list to see the additional entries.
Environment Information
The lower panel presents information concerning the device's environment, as
described in the table, below:
Item
Power Supply
The icons for Power Supply 1 and Power Supply 2 display in gray
Detection
when there is no power to the power supply – they display in blue
when power is present.
When this function is enabled (there is a check in the checkbox), if
there is only one source of power, the switch will beep constantly to
warn you of the problem.
If you are at the Local Console you will see a message asking you
to confirm that your intention is to only have one power source. If
your intention is to only have one source of power, there are two
ways to stop the beeping: 1) You can disable power supply
warnings by unchecking the checkbox. Do this if you want to
disable this function on a permanent basis.
Or, 2) you can confirm your intention in the dialog box. Do this if
you only want to disable the warning temporarily. With this method,
the warning function will be back in effect after the next system
reset.
The default for this function is enabled.