Parameter Clear; Parameters To Be Cleared - Toshiba B-EX6 Series Maintenance Manual

Table of Contents

Advertisement

5. SYSTEM MODE
<Reference: Maintenance counter printout>
<< COUNTER >>
TOTAL FEED 4.8km
FEED
0.0km ···
FEED1
4.8km
FEED2
0.0km
FEED3
0.0km
FEED4
0.0km
PRINT
0.0km ···
PRINT1
4.5km
PRINT2
0.0km
PRINT3
0.0km
PRINT4
0.0km
CUT
0 ·········
HEAD U/D
0 ·········
RIBBON
0h ·······
SOLENOID
0h ·······
232C ERR
0 ·········
SYSTEM ERR 0 ·········
POWER FAIL 0 ·········
2. LCD message while a maintenance counter clear is performed
While clearing
After the maintenance counter
clear is completed
3. After the maintenance counter clear is completed, turn off the printer when "COMPLETED. Turn off the
printer" is displayed.

5.8.3 PARAMETER CLEAR

The parameter settings are cleared and reset to the initial values for each destination.
When the printer is started for the first time after a parameter clear, the initial setting wizard is started.
This wizard enables setting the basic parameters (LCD language, use of the ribbon, media type, etc.)
required for various settings.

5.7.4.3 Parameters to be Cleared

After the parameter settings are cleared, the initial values for a selected destination are set.
 QM TYPE
 JA TYPE
 CN TYPE
Label distance covered
②Print distance
③Cut count
④Head up/down count
⑤Ribbon motor drive time
⑥Head-up solenoid driver time
⑦RS-232C hardware error count
⑧System error count
⑨Momentary power interruption count
ALL COUNTER
CLEAR...
ALL COUNTER
COMPLETED
Turn off the printer
[QM]
Display
5-55
EM18-33031
5.8 RAM CLEAR