5. SYSTEM MODE
THRESHOLD<R>
THRESHOLD<T>
<< PARAMETER SETTINGS >>
Item
Description
Value to be printed
MEDIA LOAD [ ]
[Description] Media feed to the print start position
[Values to be printed]
OFF: Disabled.
STD: Feeds the detected gap/mark to the print start position.
ECO: Feeds a gap/mark positioned between the print head and the media sensor, if any, to the print
start position.
ECO+Backfeed: Back feed follows the above ECO printer behavior.
MOVE TO TEAROFF [1] [2] [3]
[Description 1] Auto feed to the cut/strip position after printing
[Value to be printed 1]
OFF: Disabled.
ON:
Enabled. The following media stop position fine adjustment value is also printed.
[Description 2] Media stop position fine adjustment value
Note: Printed only when the "Auto feed to the cut/strip position after printing" is set to ON.
[Value to be printed 2]
-5.0mm to+5.0mm
[Description 3] Feed mode
[Value to be printed 3]
MODE1: Feeds the media for 16.5 mm.
MODE2: Feeds the media backward for 6 mm, then feeds it forward for 3 mm. (Only when the cut
mode, thermal transfer, and feed gap sensor are selected.) In other conditions, the printer
feeds the media for 16.75 mm.
MODE3: Feeds the media for 34.0 mm. This is an exclusive specification for issuing RFID media.
HEAD UP CUT/RWD [ ]
[Description] Whether to enable the head-up function during cut issue or use the Rewinder
[Values to be printed]
OFF: The head-up function is disabled during cut issue or the rewinder is not used.
ON:
The head-up function is enabled during cut issue or the rewinder is used.
RIBBON SAVE [ ]
[Description] Whether to use the ribbon saving module
[Values to be printed]
OFF:
Not used.
ON:TAG:
The ribbon saving module is used.(Head lever position: "TAG")
ON:LABEL: The ribbon saving module is used. (Head lever position: "LABEL")
*For B-EX6T1, only Position1 is available to use since there is no distinguish between Tag position
and Label position.
PRE PEEL OFF [ ]
Threshold fine adjustment for
reflective sensor
Threshold fine adjustment for
transmissive sensor
5-9
0.0V to 4.0V
0.0V to 4.0V
EO18-33031