General data
Cylinder inspection
4.3 -
M
AJOR INSPECTION
A thorough inspection of the structural parts must be realized all the 5000 h or 10 years with disassembling
of the element to check the entirety of the welding. Each Cylinder must be disassembled and must be review
using non-destructive checks.
The criteria quoted above are applicable :
• Absence of deformation and visible damage.
• Absence of crack, broken welding, oxidation, glare of painting.
Check :
1.
Pipe weld connection.
2.
Rod weld connection.
3.
Ring.
4.
Rod.
5.
Piston.