Haulotte Compact 8 Maintenance Book page 44

Hide thumbs Also See for Compact 8:
Table of Contents

Advertisement

General data
Structural part inspection
4 - Control and maintenance
To guarantee the integrity of the machine, it is necessary to carry out periodical controls on the mechanical structure
such as defines hereafter.
4.1 -
D
AILY INSPECTION
All the accessible structural part without disassembling
must be subjected to a fast visual inspection.
If anomalies are noted, according to the list below, a
reinforced control will have to be carried out to judge
conformity of the part :
• Absence of foreign body to the articulations and
slides.
• Absence of deformation and visible damage.
• Absence of crack, broken welding, oxidation, glare of
painting.
• Absence of excessive gap to the articulations and
slides.
• Check that locking device are not damaged and are
functional.
• No screws or missing part loosened or unscrew.
• Anchorage points firmly fixed and not damaged.
The list of part to check are define Section
Familiarization.