Section 1: Introduction; Scope; 1: Reference Documentation - Honeywell Fire-Lite Alarms MS-9200 Wiring Manual

Intelligent control panel, slc
Table of Contents

Advertisement

1.1 Scope

This document describes the operation, installation and wiring of various Signaling Line Circuit (SLC) devices when used with the Fire-
Lite MS-9200, MS-9200E, MS-9600, MS-9600E, MS-9600LS, MS-9600LSC, MS-9600LSE, MS-9600UDLS, MS-9600UDLSE,
MS-9200UD, MS-9200UDE, MS-9200UDLS, MS-9200UDLSE, MS-9200UDLSC, MS-9050UD, MS-9050UDC, MS-9050UDE, ES-
50X, ES-50XC, ES-200X, and ES-200XC control panels. It also provides basic information that applies to Fire•Lite SLC loops in gen-
eral, such as the branch resistance measurements.
NOTE: Any reference in this manual to the MS-9200, MS-9200UD, MS-9200UDLS, MS-9600, MS-9600LS, MS-9600UDLS, MS-9050UD,
ES-50X, or ES-200X includes the MS-9200E, MS-9200UDE, MS-9200UDLSE, MS-9200UDLSC, MS-9600E, MS-9600LSE, MS-9600LSC,
MS-9600UDLSE, MS-9050UDC, MS-9050UDE, ES-50XC, or ES-200XC respectively unless otherwise specified.
Additional information about the specific control panel and the modules and detectors referenced in this document can be found in the
respective installation manual as listed in Section 1.1.1, "Reference Documentation".
Currently, there are two styles of modules available, legacy version and newer version. The obvious difference between the two styles is
the orientation of the rotary dials. Refer to the diagram below for an example of each.
NOTE: Only the MMF-300, MMF-302, CRF-300, CMF-300, and MDF-300 modules are available as newer type modules. Both the legacy
and newer versions share the same part numbers. The newer version modules will be phased in, replacing the legacy version. This manual
contains information and wiring diagrams for the newer version of the modules. Refer to "Terminal Conversion Charts for New & Legacy
Devices" on page 69 for additional information.
Currently, there are two styles of detector bases available, legacy version and newer version. The obvious difference between the two
styles is the orientation of the screw terminals. Refer to Section 9 and Appendix D for an illustration of each.
NOTE: Only the B501 Detector Base, B210LP Detector Base (replacement base for B350LP), B224RB Relay Base, and B224BI Isolator
Base are available as newer type bases. Both the legacy and newer versions share the same part numbers. The newer version bases will
be phased in, replacing the legacy version. This manual contains information and wiring diagrams for the newer version of the bases. Refer
to "Intelligent Detector Base Layouts for Legacy Devices" on page 72 for additional information.
1.1.1 Reference Documentation
The table below accommodates a list of document sources containing additional information regarding the devices used on a Signaling
Line Circuit:
For information on...
MS-9200, MS-9200E
MS-9600, MS-9600E
MS-9200UD, MS-9200UDE Control Panels
MS-9200UDLS, MS-9200UDLSE, MS-9200UDLSC Control Panels
MS-9600LS, MS-9600LS(C/E) & MS-9600UDLS, MS9600UDLSE Control Panels
MS-9050UD, MS-9050UDC, MS-9050UDE Control Panels
ES-50X, ES-50XC Control Panels
ES-200X, ES-200XC Control Panels
Compatible Devices
Wireless Sensor Network
BG-12LX Pull Station
MMF-300 Monitor Module
MMF-300-10 Monitor Module
8

Section 1: Introduction

CMF-300
Legacy Version Module
(Vertical Rotary Dial)
CMF-300
Newer Version Module
(Horizontal Rotary Dial)
Refer to...
Instruction Manual
Instruction Manual
Instruction Manual
Instruction Manual
Instruction Manual
Instruction Manual
Instruction Manual
Instruction Manual
Device Compatibility
Document
Instruction Manual
Installation Instructions
Installation Instructions
Installation Instructions
FireLite SLC Wiring Manual — P/N 51309:R3 7/29/2019
Part Number
51003
51335
51906
52750
52646
52413
LS10129-000FL-E
LS10131-000FL-E
15384
LS10036-000FL-E
I56-3655
I56-1191 / I56-3653
I56-1873

Hide quick links: