Unresponsive Ap; Resetting To Factory Default - Alvarion WBSIac User Manual

Table of Contents

Advertisement

Chapter 3 - Final Notes
3.1.6

Unresponsive AP

Symptom:
The WBSIac AP does not respond.
Solution:
Turn off the WBSIac AP for 10 seconds and then turn it on again.
3.2

Resetting to Factory Default

To reset the WBSIac AP to factory default settings while the power is on, hold down the reset button for
8 seconds and then release.
Another method is to enter the following command into the WBSIac AP's Linux terminal:
mtd -r erase rootfs_data
After a while, the flash would be erased and the WBSIac AP would reboot into its factory default state.
The firmware version remains the same as the latest firmware loaded onto the board.
WBSIac Access Point User Ma n ua l