Setting Value
1h-7h
Setting Value
0h
Setting Value
8h-Fh
Adjustment of duty
Duty can be changed by the parameter of Table 11.3-3. Moreover, as shown in Table 11.3-4, a setting value is
changed, and the amount of duty can be adjusted. Please refer to Fig 11.3-2 about the situation of change.
DUH1
DUH2
DURG
DUSHP
DUSHD
DURS
Fig 11.3-1 Adjustment of delay
Table 11.3-3 Adjusting parameter of duty
Parameter
CAT6_Byte12_bit0-3
CAT6_Byte12_bit4-7
CAT6_Byte13_bit0-3
CAT6_Byte13_bit4-7
CAT6_Byte14_bit0-3
CAT6_Byte14_bit4-7
175
- SS-HQ1 Application Notes -
Description
Adjustment of H1duty
Adjustment of H2duty
Adjustment of RG duty
Adjustment of XSHP duty
Adjustment of XSHD duty
Adjustment of XRS duty
Ver.1.0.0 January 7, 2005