Blemish address resetting
This parameter is used to reset the values of parameters storing blemish detection results (all values are set to
"00[h]").
Note that if blemish detection results are written to EEPROM (blemishes detected through static detection), the
EEPROM values are not reset. This parameter resets the blemish detection results that have been applied to
registers. (To reset EEPROM data, write "00[h]" to EEPROM.)
If this parameter is set to "1[h]" (reset ON), the blemish detection operation will not be performed, so normally it
should be set to "0[h]".
Parameter
ADDRRST
* These parameters can be used for both static detection and dynamic detection.
* Enabled when DYNDETON=0[h] and DYNDELON=0[h]
Blemish correction count setting
The maximum number of detected blemishes is always 32. However, the number of corrections is set using
the following parameter.
Table 11.2-17 Parameter for setting the number of blemish corrections
Parameter
DEFNUM
CAT11_Byte3_bit2-6
* These parameters can be used for both static detection and dynamic detection.
Dynamic detection wait field count setting
In dynamic detection mode, the address with the highest-level blemish in a frame is compared with the
addresses N fields before and following. It is stored as a blemish only if it matches. This parameter can be
used to set the number of fields N.
Table 11.2-18 Parameter for setting dynamic detection wait field count
Parameter
FLDWAIT
CAT11_Byte4_bit0-7
Dark level reference value setting
This parameter is used to set the dark level reference value, which serves as a reference during dynamic
detection.
Table 11.2-19 Parameter for setting dark level reference value
DARKREFL
DARKREFM
Table 11.2-16 Parameter for resetting blemish address
0[h]: Normal blemish detection operation
CAT11_Byte18_bit0
1[h]: Resets blemish detection results
Correction count setting
0[h]:1 correction - 1F[h]:32 corrections
Dynamic detection wait field count
(in frame increments, so only even numbers can be set)
Parameter
CAT11_Byte8_bit0-7(LSB)
CAT11_Byte9_bit6-7(MSB)
Description
Description
Description
Description
Dark level reference value setting
169