SET COOL DOWN TIME
SET METRICS DEFAULT
SET SPEED LIMIT
SET INCLINE LIMIT
HIDDEN PROGRAMS
REMOTE SPEED CONTROL
AUTOSTOP CONFIGURE
SET CUSTOM PROGRAM 1
SET CUSTOM PROGRAM 2

Information Display (65)

Information Display Access: press STOP/PAUSE/REST > 6,5
ITEM
ODOMETER
HOUR METER
BELT RATING
U-BOOT SW
U-BASE SW
LOWER SW
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Sets the amount of time that a cool down period will occur at the end of
every workout. Factory default is 5 minutes. Settable in 1 minute
increments.
Sets a metric that may be of specific importance to the specific facility or
fitness trainer. The selected metric will scroll across the screen at regular
intervals during the workout.
Factory default is "NONE".
Sets the maximum speed the user can set the unit to.
Factory default is 12 MPH.
Sets the maximum value the user can set the unit to.
Factory default is 15%.
Either enabled or disabled, the setting allows the unit to access specialized
fitness tests designed for police, fire fighters and the military.
Factory default is disabled.
Not currently used or supported in software.
Sets the Auto Stop setting to On or Off. Factory default is "ON"
Intended for a custom program to be programmed if the tread is used in a
residential setting.
Intended for a custom program to be programmed if the tread is used in a
residential setting.
Displays the total number of accumulated miles on the unit.
This value is stored in the upper PCA in the console so if the
PCA is replaced the accumulated miles would start again from "0".
Displays the total number of hours that the unit took to accumulate unit miles.
This value is stored in the upper PCA in the console so if that PCA is replaced the
hours of use would start again from "0".
Displays a belt rating from 10 (best) to 0 (worst). Resettable to 10 by holding
QuickStart.
Displays the current version of boot-up software for the upper PCA (console).
Displays the current version of software loaded in the upper PCA (console).
This is the unit specific console software.
Displays the current version of software loaded in the Machine Controller.
DESCRIPTION