Graco LSR Select Instructions Manual page 99

Table of Contents

Advertisement

Pressure Log Screen:
This screen is reached by the DATA LOGS push button 
at the bottom of every screen. This is useful for set up 
and troubleshooting. The screen is very useful when 
the kit 24M127 is used. On the basic system alone this 
only displays the base pressure.   Once the PRESSURE 
LOG screen is up, new buttons show up along the bot‐
tom of the screen for further diagnostics.
1. CLEAR PRESS. FAULT push button: This is used
to clear a pressure fault.
2. BASE/INHIBITOR/CATALYST/COLOR/BLOCK
OUT pressure readouts: These appear along right
side of the screen and display the current pressure
of each component.
NOTE: The colors match the line colors on the chart.
3. DATA LOG CONTROLS window: This contains
push buttons to navigate around the chart.
a. UP SCALE push button: Moves the PSI scale
on the left side of the chart up to view a higher
pressure range.
3A2152B
Appendix A - HMI Screens Overview
b. DOWN SCALE push button: Moves the PSI
scale on the left side of the chart down to view a
lower pressure range.
c. PEN push button: Changes scaling based on
the pen color (component).
d. MOVE LEFT/MOVE RIGHT push buttons:
These scroll the time on the X axis to the right or
left.
e. PAUSE push button: Stops the chart from
recording.
f.
HOME push button: Moves the chart to the time
the recording started.
g. END push button: Starts the chart again if
paused and moves to the current time.
4. BASE/CATALYST/COLOR/INHIBITOR Push but-
tons: These bring up screens for each component
for further information and troubleshooting.
99

Advertisement

Table of Contents
loading