Troubleshooting

Drive Faults

The drives have a diagnostic window that should have a "4" when everything is normal.
If a drive has a problem, a series of numbers flash in this window. Below is a list of error codes.
Error
Fault Message
Code
RSLogix (HIM)
General
E00
BusUndervoltage
Fault (Blown fuse)
30
Problem or Symptom
Power (PWR) indicator
not ON
Motor jumps when first
enabled
Digital I/O not working
correctly
A blown fuse was
detected on the inverter
PCB
Potential Cause
No ac power or auxiliary
logic power.
Internal power supply
malfunction.
Motor wiring error.
Incorrect motor chosen.
I/O power supply discon-
nected.
Blown fuse.
ti18126a
Possible Resolution
Verify ac control power is
applied to the Kinetix 2000
system.
Call your Rockwell Automa-
tion sales representative to
return module for repair.
Check motor wiring.
• Run Hookup test in RSLogix
5000 software.
Verify the proper motor is
selected.
Verify connections and I/O
power source.
Call your Rockwell Automa-
tion sales representative to
return module for repair.