Omron Z500-SW2T Setup Manual page 70

Profile measuring system
Table of Contents

Advertisement

SECTION 4
Appendix
Z500
68
Setup Manual
Item
Input/Output Type
Results output
Perfor-
mance
specifica-
Terminal block
tions
Monitor interface
Analog output resolution
Power supply voltage
Current consumption
Insulation resistance
Dielectric strength
Leakage current
Noise resistance
Vibration resistance
General
specifica-
Shock resistance
tions
Ambient temperature
Ambient humidity
Ambient environment
Ground
Degree of protection
Material
Weight (including packag-
ing)
Accessories
Note:
For measurement at an average number of times of 64 with an OMRON K3AS Linear Sen-
sor Controller connected.
Model
Z500-MC10E
NPN
Judgment output
RS-232C output
Terminal block output
Measurement value output (measurement value)
RS-232C output
Analog output
11 input points: TRIGGER, LD-OFF, RESET, D10 to D17
21 output points: DO0 to DO19, GATE
1CH (for pin jack or overscan monitor)
The full scale for output can be divided into a maximum
of 40,000 gradations.
Resolution (See note): 0.25 mV (±5 V), 0.4 µ A (4 to 20
mA)
21.6 to 26.4 VDC
1 A max. (with 2 Sensors connected)
20 M Ω min. between all DC external terminals and GR
terminal (100 VDC megger)
(with internal surge absorber removed)
1000 VAC, 50/60 Hz between all DC external terminals
and GR terminal
(with internal surge absorber removed)
10 mA max.
1500 Vp-p; pulse width: 0.1 µ s/1 µ s, Rising edge: 1-ns
pulse
10 to 150 Hz (double amplitude: 0.1 mm) for 8 min.
each in X, Y, and Z directions
2
200 m/s
, 3 times each in 6 directions
Operating: 0 to +50 °C, Storage: -15 to +60 °C
(with no icing or condensation)
Operating and storage: 35 to 85 %RH
(with no condensation)
No corrosive gases
Ground the Z500's ground terminal to less than 100 Ω .
IEC IP20 (in-panel)
Unit: ABS
Approx. 1300 g (Unit: Approx. 700 g)
2 manuals, 1 resistor (250 Ω , 1/2 W)
Z500-MC15E
PNP

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z500-sw6Z500-sw17

Table of Contents