INTRODUCTION
Turning OFF the Power
Using the RESET Signal
Securing the Video Monitor (When Using the Recommended F150-M09)
Warming Up
Z500
16
Setup Manual
Do not turn OFF the power while a message is being displayed indicating that
processing is being performed. Data in memory will be destroyed, and the Z500
may not operate correctly the next time it is started.
Scn 0
Saving
Do not input the RESET input immediately after power is turned ON. When
using the RESET input to synchronize startup timing, wait at least 1 second after
the Z500's power supply is turned ON before turning ON the RESET terminal.
If the video monitor case is metallic, observe the following precautions to
prevent noise interference, because the video monitor case is connected to the
0V line in the internal circuits.
• Do not ground the video monitor.
• Do not ground the metallic part of the connector.
• Secure the video monitor with plastic screws if it is being mounted to a
metallic surface.
After turning
ON the power
before use. The circuits are unstable immediately after the power supply is
turned ON and attempting measurement may result in inconsistent measurement
values.
Save
supply, allow the Z500 to stand for at least 30 minutes