Omron Z500-SW2T Setup Manual page 55

Profile measuring system
Table of Contents

Advertisement

3-2-2 Wiring
The maximum cable length is 15 m.
Standard Wiring
Wiring for RS/CS Control
3-2-3 Connection
Align the connector with the socket and press the connector straight into place.
Tighten the two screws on the edges of the connector.
NOTICE
Z500
Signal
Pin No.
SD (TXD)
2
RD (RXD)
3
RS (RTS)
4
CS (CTS)
5
9
SG (GND)
Z500
Signal
Pin No.
SD (TXD)
2
3
RD (RXD)
RS (RTS)
4
5
CS (CTS)
9
SG (GND)
* Pin numbers on the external device will depend on the device being connected.
Refer to the manual for the personal computer or PLC being connected.
• Always turn OFF the power supply before connecting or disconnecting cables. The
peripheral device may be damaged if connected or disconnected with the power supply
turned ON.
• Always tighten the connector screws.
Connecting External Devices
Pin No.
Use a shielded cable.
Pin No.
Use a shielded cable.
Z500
MULTI-DIMENSION CONTROLLER
SECTION 3
External device
Signal
*
SD (TXD)
*
RD (RXD)
*
RS (RTS)
*
CS (CTS)
*
SG (GND)
External device
Signal
*
SD (TXD)
*
RD (RXD)
*
RS (RTS)
*
CS (CTS)
*
SG (GND)