Omron Z500-SW2T Setup Manual page 29

Profile measuring system
Table of Contents

Advertisement

1-4-3 Wiring the Power Supply
Wire the Power Supply Unit independently of other devices. In particular, keep
the power supply wired separately from inductive loads.
Use a power supply that meets the following specifications.
Recommended Power Supply
Recommended Model
CHECK
Output current
Power supply voltage
1.6 A min.
24 VDC (21.6 to 26.4VDC)
Manufacturer
OMRON Corp.
S82K-05024
• Use a DC power supply with countermeasures against high-voltage spikes (safe extra
low-voltage circuits on the secondary side). Excessively high voltages can result in
electric shock.
• If UL recognition is required, use a UL class II power supply.
• Keep the power supply wiring as short as possible (less than 10 m).
+
24 VDC
POWER
Model
-
DI 1
DI 2
DI 1
SECTION 1
Wiring and Connection
DI 4
DI 6
DI 3
DI 5
DI 7
Z500
Setup Manual
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z500-sw6Z500-sw17

Table of Contents