In order to keep the Grand Prix™ running smoothly and reduce
the risk of damage to the machine and subsequent downtime,
Mytee recommends following the maintenance schedule below:
Maintenance Item
Clean and inspect tanks.
Clean and inspect hoses.
Check and clean internal filters.
Check power supply cable.
Clean machine with all-purpose cleaner
and cloth.
Check spray nozzles.
Flush solution system with Mytee

System Maintainer.

Inspect vacuum hoses for holes and
loose cuffs.
Inspect spray pattern for clogging.
If clogged, remove spray tips and
soak them in a recommended liquid
neutralizer for up to six hours. To
remove spray tip, twist spray tip body
counter-clockwise.
Lubricate casters with water resistant
oil.
Inspect machine for water leaks and
loose hardware.

3.1 - Opening the Unit for Maintenance

To open your Grand Prix™ for maintenance, use a drill with a
3/8" bit to remove the bolts holding the Grand Prix's™ body
together. Lift up on the push handle to open the machine like a
clam shell.

3.2 - Filter Maintenance

The Grand Prix™ has a small filter at the top of the vacuum
stack in the recovery tank. This filter should be checked after
each use.
3.3 - System Maintainer
Regular flushing of the solution system with Mytee System
Maintainer keeps your extractor running efficiently by removing
hard water scaling that builds up in the system.
How to use System Maintainer:
1. Thoroughly mix System Maintainer with warm water at a 1:1
ratio in a separate container. Pour into your Extractor's solution
tank.
Daily
Weekly
X
2. Connect a cleaning tool (upholstery tool, wand, etc.) and
X
remove the jet(s) in order to prevent clogging from dislodged
X
mineral build-up.
X
3. Turn on the Extractor's pump and run the System Maintainer
X
solution through the system and into a bucket or receptacle
until you have a solid stream.
X
4. Let sit for about 5 minutes while the System Maintainer
X
solution does its job inside your Extractor.
X
5. Finish running the rest of the solution through the system.
6. Run clean water through the system to flush out any
remaining System Maintainer.
X
X
X
11

3 - Machine Maintenance

Do not tamper with the set screw on the
pump pressure switch. This can damage the
pressure switch.