Page 1
User Manual Grand Prix Model: ™ HP120 REV. 12/4/19 13655 Stowe Dr. Poway, CA 92064 P: (858) 679-1191 F: (858) 726-6005 www.mytee.com...
Page 2
Congratulations on the purchase of your new Grand Prix™ Automotive Detailing Extractor. As technology continues to develop you can work confidently knowing that both Mytee Products and its employees are equally dedicated to developing with the industry and its advances.
Table of Contents Important Safety Information At a Glance 1.1 - Technical Specifications 1.2 - Included with the Grand Prix™ 1.3 - Grand Prix™ Front View 1.4 - Grand Prix™ Rear View Machine Operation 2.1 - Powering the Grand Prix™ 2.2 - Filling the Solution Tank 2.3 - Connecting the Hoses 2.4 - Operating the Grand Prix™...
This machine must be grounded. If it should malfunction or When and if calling Mytee for support, please have your break down, grounding provides a path of least resistance Model and Serial Number available for faster assistance.
Page 5
Important Safety Information 3. Always unplug power cord from electrical outlet before attempting any adjustments or repairs. 4. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. 5. Do not pull or carry by cord. Do not close a door on cord or pull cord around sharp edges or corners.
1 - At a Glance 1.1 - Technical Specifications Solution Tank 10 gallon capacity Recovery Tank 9 gallon capacity Single 3-stage low amp Vacuum Motor 100 CFM, 130” water lift 120 PSI diaphragm pump Pump 1.3 GPM 1,200W REAL HEAT™ system Heater 210º...
1 - At a Glance 1.3 - Grand Prix™ Front View 1. Clear recovery tank lid 6. Rear foam-filled wheels 2. Switch plate 7. Solution line quick connect 3. Solution tank lid 8. Vacuum hose Cuff-Lynx™ connection 4. Solution tank 9.
2 - Machine Operation 2.1 - Powering the fitting on the front of the machine. ♦ Grand Prix™ 2.4 - Operating the Grand Prix™ Plug the power cord from the Grand Prix™ into a standard grounded wall outlet. The Grand Prix™ operates off a single, grounded 20 amp outlet.
In order to keep the Grand Prix™ running smoothly and reduce the risk of damage to the machine and subsequent Weekly flushing of the solution system with Mytee® downtime, Mytee recommends following the maintenance System Maintainer helps keep lines clean and prevents...
4 - Troubleshooting 4.1 - Vacuum Troubleshooting 4.2 - Pump Troubleshooting Vacuum is not turning on. Pump doesn’t turn on. Possible Cause Solution Possible Causes Solutions Vacuum may not be getting Check for faulty connec- Bad switch at control panel. Unbolt the switch plate. power.
Page 12
Observe the proper orien- for leaks. If there are no tation (flow direction) of the leaks, run Mytee’s System check valve. Maintainer™ through the machine to clear NEVER OPERATE A UNIT blockages.
4 - Troubleshooting 4.3 - Heater Troubleshooting Heater has hard water Run Mytee System Maintainer™ (Part # 3601) buildup inside, leading to Heater is not heating water. lost efficiency. through the machine regularly in order to clear Possible Causes Solutions...