Certification
6.2 EMC and Environmental Type Tests
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RSG908C has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
61000-4-2
61000-4-3
61000-4-4
61000-4-5
61000-4-6
61000-4-8
34
EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
EN50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
EN 50155
Railway applications – Rolling stock – Electronic equipment
Test
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
IEC
Surge
IEC
Induced (Conducted) RFI
IEC
Magnetic Field
Description
Enclosure
Contact
Enclosure Air
Enclo-
sure Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Earth
Ground Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Earth
Ground Ports
Enclo-
sure Ports
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
10 V
10 V
10 V
10 V
100 A/m Continuous
1000 A/m for 1 s
Installation Manual, 02/2020, C79000-G8976-1404-06
Severi-
ty Levels
4
4
4
4
4
4
4
3
4
3
3
3
3
 
RUGGEDCOM RSG908C